Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 7 Card Provisioning
Provisioning Electrical Cards
Step 5
Click Apply.
Step 6
Repeat Steps 4 – 5 for each subtab that has parameters you want to provision.
7.2.4 DS3XM-6 Card Parameters
The DS3XM-6 transmux card can accept up to six DS-3 signals and convert each signal to 28 VT1.5s.
Conversely, the card can take 28 T-1s and multiplex them into a channeled C-bit or M23 framed DS-3.
Unlike the DS3-12 and DS3N-12 cards, the DS3XM-6 allows circuit mapping at the VT level.
Conversely, the card can take 28 T-1s and multiplex them into a channeled C-bit or M23 framed DS-3.
Unlike the DS3-12 and DS3N-12 cards, the DS3XM-6 allows circuit mapping at the VT level.
shows parameters that you can provision for each port.
Sonet
Thrshld
Thrshld
CV
Coding violations
Numeric. Defaults (Near End STS
termination):
termination):
•
15 (15 minutes)
•
125 (1 day)
ES
Errored seconds
Numeric. Defaults (Near End STS
termination):
termination):
•
12 (15 minutes)
•
100 (1 day)
FC
Failure count
Numeric. Defaults (Near End STS
termination):
termination):
•
10 (15 minutes)
•
10 (1 day)
SES
Severely errored seconds
Numeric. Defaults (Near End STS
termination):
termination):
•
3 (15 minutes)
•
7 (1 day)
UAS
Unavailable seconds
Numeric. Defaults (Near End STS
termination):
termination):
•
10 (15 minutes)
•
10 (1 day)
Alarming
Port
Port number
1 - 12
Profile
Sets the alarm profile for the
port.
port.
•
Default
•
Inherited
•
Custom profiles (if any)
Suppress
Alarms
Alarms
Suppresses alarm display for the
port.
port.
•
Unselected (default)
•
Selected
Table 7-4
DS3E Card Parameters (continued)
Subtab
Parameter
Description
Options