INSTALLATION • OEM650/OEM650X
6
3. Slide the drive cover back on.
4. Attach the motor (to A+, A-, B+, B-).  Do not connect the motor to
the load at this time (refer to Figure 2-2 for 23 size motors or
Figure 2-3 for 34 size motors).  OEM size 23 motors may be wired
in a series or parallel configuration.  If you are using a 75VDC
power supply (OEM300) with the drive or drive indexer, Compumo-
tor recommends that you use a series configuration, however; a
parallel configuration should be used when the power supply is
24VDC - 48VDC.  Parallel configurations will cause the drive to
dissipate slightly more heat than a serial configuration.  This
increase in drive temperature will not affect the unit's performance,
but it may adversely affect heat-sensitive devices that are stored
within the same enclosure.
RED
BLUE
GREEN
ORANGE
YELLOW
BLACK
BROWN
WHITE
Top View
RED
BLUE
GREEN
ORANGE
YELLOW
BLACK
BROWN
WHITE
Top View
A-
B-
A+
B+
OEM
s
e
r
i
e
s
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A- 
B+
B- 
POWER
FAULT
}
OEM
s
e
r
i
e
s
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A- 
B+
B- 
POWER
FAULT
}
  Size 23 motors may be wired in series or parallel configurations         
     (OEM57-40-MO, OEM57-51-MO, OEM57-83-MO)
A-
B-
A+
B+
Size 23 OEM650 Motors:  Series Wiring
Size 23 OEM650 Motors:  Parallel Wiring
Figure 2-2.   NEMA 23 Size OEM Motor Wiring—Series & Parallel