7.5.4 
LBU Write to ERTEC 200 with common Read/Write line (LBU_RDY_N active low) 
LBU_CS_R_N/ 
LBU_CS_M_N 
LBU_WR_N 
LBU_A(20:0)/ 
LBU_SEG(1:0)/ 
LBU_BE(1:0)_N 
LBU_RDY 
LBU_D(15:0) 
WCS
 
ACS
CRE
 
CDV
 
CDH
 
CAH
 
CWH
 
t
RTC
t
RAP
WR
 
 
 
Figure 16: LBU-Write-Sequence with common RD/WR line 
Parameter Description 
Min 
Max 
t
WCS
write signal asserted to chip select setup time 
2 ns
1
 
t
ACS
address valid to chip select asserted setup time 
0 ns 
 
t
CRE
chip select asserted to ready enabled delay 
5 ns 
12 ns 
t
CDV
chip select asserted to data valid delay 
 
40 ns 
t
RAP
ready active pulse width 
17 ns 
23 ns 
t
CWH
write signal deasserted to chip select deasserted hold time 
0 ns 
 
t
CAH
address valid to chip select deasserted hold time 
0 ns 
 
t
RTC
ready asserted to chip select deasserted delay 
0 ns 
 
t
CDH
data valid/enabled to chip select deasserted hold time 
0 ns 
 
t
WR
write recovery time 
25 ns 
 
 
Table 28: LBU Write access timing with common Read/Write line 
1
  The setup time 
t
WCS 
must be maintained under all circumstances; otherwise the LBU unit drives the ERTEC 200 
databus. 
 
The ERTEC 200 has two LBU chip select inputs. One for access to the page configuration register (LBU_CS_R_N) and 
one to access to the ERTEC 200 memory address space (LBU_CS_M_N). Only one of these chip select signals may be 
active at a time and it is not allowed to change the chip select during the complete access.  
7.6  Host Interrupt Handling: 
The ERTEC 200 generates 2 interrupt signals, LBU_IRQ0_N and LBU_IRQ1_N, to the external host. Both interrupts are 
generated in the IRT switch interrupt controller. Both signals are set by default to Low Active. However, they can also be 
assigned different parameters in the IRT switch. 
 
Mailbox handling between the ARM946E-S and an external host is possible via the IRT switch interrupt controller.   
An interrupt request from the ARM946E-S to the host processor is initiated by writing to the Activate_HP_Interrupt 
register. 
An interrupt request from the host processor to the ARM946E-S is initiated by writing to the Activate_SP_Interrupt 
register. 
 
Both registers can only be written to. Any value can be written.  
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
82
             
ERTEC 200 Manual 