Siemens ERTEC200 Manual De Usuario

Descargar
Página de 97
 
 
7.7  Address Assignment of LBU Registers 
The LBU registers are 16 bits in width. These registers can only be written to with words. The LBU paging configuration 
registers are addressed via the "LBU_CS_R_N” input. 
 
LBU 
Register Name  Offset Address  Address Area
Access 
Default 
Description 
LBU_P0_RG_L 
0x0000 
2 bytes 
W/R 
0x0000 
LBU pagex range register 0 Low 
LBU_P0_RG_H 
0x0002 
2 bytes 
W/R 
0x0001 
LBU pagex range register 0 High 
LBU_P0_OF_L 
0x0004 
2 bytes 
W/R 
0x0000 
LBU pagex offset register 0 Low 
LBU_P0_OF_H 
0x0006 
2 bytes 
W/R 
0x1010 
LBU pagex offset register 0 High 
LBU_P0_CFG 
0x0008 
2 bytes 
W/R 
0x0000 
LBU configuration register 0 
LBU_P1_RG_L 
0x0010 
2 bytes 
W/R 
0x0000 
LBU pagex range register 1 Low 
LBU_P1_RG_H 
0x0012 
2 bytes 
W/R 
0x0010 
LBU pagex range register 1 High 
LBU_P1_OF_L 
0x0014 
2 bytes 
W/R 
0x0000 
LBU pagex offset register 1 Low 
LBU_P1_OF_H 
0x0016 
2 bytes 
W/R 
0x1000 
LBU pagex offset register 1 High 
LBU_P1_CFG 
0x0018 
2 bytes 
W/R 
0x0001 
LBU configuration register 1 
LBU_P2_RG_L 
0x0020 
2 bytes 
W/R 
0x0000 
LBU pagex range register 2 Low 
LBU_P2_RG_H 
0x0022 
2 bytes 
W/R 
0x0020 
LBU pagex range register 2 High 
LBU_P2_OF_L 
0x0024 
2 bytes 
W/R 
0x0000 
LBU pagex offset register 2 Low 
LBU_P2_OF_H 
0x0026 
2 bytes 
W/R 
0x3000 
LBU pagex offset register 2 High 
LBU_P2_CFG 
0x0028 
2 bytes 
W/R 
0x0000 
LBU configuration register 2 
LBU_P3_RG_L 
0x0030 
2 bytes 
W/R 
0x0800 
LBU pagex range register 3 Low 
LBU_P3_RG_H 
0x0032 
2 bytes 
W/R 
0x0000 
LBU pagex range register 3 High 
LBU_P3_OF_L 
0x0034 
2 bytes 
W/R 
0x2000 
LBU pagex offset register 3 Low 
LBU_P3_OF_H 
0x0036 
2 bytes 
W/R 
0x4000 
LBU pagex offset register 3 High 
LBU_P3_CFG 
0x0038 
2 bytes 
W/R 
0x0001 
LBU configuration register 3 
Table 29: Overview of LBU Registers 
7.8  LBU Register Description 
LBU_P0_RG_L
 
 
W/R    Addr.: LBU_CS_R_N+0x00      Default: 0x0000_0000
 
LBU_P1_RG_L
 
 
W/R    Addr.: LBU_CS_R_N+0x10      Default: 0x0000_0000
 
LBU_P2_RG_L
 
 
W/R    Addr.: LBU_CS_R_N+0x20      Default: 0x0000_0000
 
LBU_P3_RG_L
 
 
W/R    Addr.: LBU_CS_R_N+0x30      Default: 0x0000_0800
 
Description 
Low word of LBU Pagex_Range_register 
 
Bit No. 
Name 
Description 
15..0 
 
Lower 16 bits for area setting 
15:8 are read/write accessible 
7:0 are read-only (value: 00h) 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
83
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0