Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
SCALANCE X-200 
Operating Instructions, 12/2011, A5E00349864-19 
207
 
6.3.5.25 
The "Agent E-Mail Config" WBM menu 
Agent E-Mail Configuration - Network monitoring with E-mails 
An IE Switch X-200 provides you with the option of automatically sending an E-mail (for 
example to a network administrator) if an alarm event occurs. The E-mail contains the 
identification of the sending device, a description of the cause of the alarm in plain language, 
and a time stamp with the time since the device started up. This allows centralized network 
monitoring to be set up for networks with few nodes based on an E-mail system. When an E-
mail event message is received, the WBM can be started by the browser using the 
identification of the sender to read out further diagnostic information. 
E-mails can only be sent when 
●  the E-mail function is activated on the IE Switch X-200 and the E-mail address of the 
recipient is configured. 
●  the E-mail function is enabled for the relevant event. 
●  there is an SMTP server in your network that can be reached by the IE Switch X-200. 
●  the IP address of the SMTP server is entered on the IE Switch X-200. 
 
Figure 6-30  "E-Mail Configuration" dialog 
E-Mail Address 
Here, you enter the E-mail address to which the IE Switch X-200 sends an E-mail if a fault 
occurs. 
SMTP Server IP Address 
Here, you enter the IP address of the SMTP server over which the E-mail is sent.