Siemens SCALANCE X-200 Manual De Usuario

Descargar
Página de 296
 
Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
SCALANCE X-200 
Operating Instructions, 12/2011, A5E00349864-19 
209
 
6.3.5.26 
The "Agent Time Config" WBM menu 
Agent Time Client Configuration 
This dialog is used to configure the time protocols. 
 
Figure 6-31  Agent Time Client Configuration dialog 
Current system time 
Either the time since the last restart or the current time is displayed here. 
If the time is received from a "non-time server", the text "not synchronized" is displayed. 
Enable time client 
The time function can be enabled and disabled here. 
Time client type 
You can choose from four different protocol types here: 
●  SNTP Poll 
If you choose this protocol type, you have to define further settings: 
Time zone offset, Time server, Init poll interval, Poll interval. 
●  SNTP Listen 
In this mode, you can also select an offset to the time received from the server. Other 
settings are not possible.