   Chapter 1 
D
V
S-9000 Functions
C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB03C01-WW.fm
masterpage:Left
132
Setup
DVS-9000/9000SF
3-704-674-01 (1)
Setup Relating to the Router Interface and Tally 
Interface
Carry out settings relating to the interface with the routing switcher, and 
settings relating to the tally interface.
You can make the following settings.
Router interface setup (Router)
• Matrix Size: Assign the switcher matrix of each switcher processor to S-Bus 
space, and select the matrix size and positioning level, source address 
settings, and so on.
• External Box: To obtain the signal selection status of external devices with 
a parallel input, assign a matrix as an external selector in the S-Bus space. 
Make the matrix size, assignment level, source address, and other settings.
Tally interface setup (Tally)
Group tally settings (Group Tally)
• Tally Group: Select the group tally (Gp1 to 4 or Gp5 to 8) which can be 
used.
• S-Bus Tally Enable: Specify S-Bus tally enabled or disabled.
Wiring information input (Wiring)
Input the information which specifies the physical wiring between switcher 
and routing switcher or between two routing switchers.
Tally enable settings (Tally Enable)
Specify the destination to be the reference for tally generation, and make 
various settings.
• Tally Type: Specify the tally type. The tally types which can be specified are 
as follows:
When Group Tally is Gp1 to 4: R1, R2, R3, R4, G1, G2, G3, G4
When Group Tally is Gp5 to 8: R5, R6, R7, R8, G5, G6, G7, G8
• Destination: Specify the address and level.
• Tally Enable: Specify the timing at which a tally is enabled.
Enable: Always enabled.
Disable: Always disabled.
Tally Input No.: Follow the tally input status.
Copy (Tally Copy)
Copy the tally information pertaining to a particular source to a different 
source.