Sony DVS-9000 Manual De Usuario

Descargar
Página de 300
   Chapter 5 
Wipes
C:\WINNT\Profiles\Administrator\Desktop\WORK_08_21\370467401
DVS9000WW\01GB07C05-WW.fm
masterpage:Left
254
Wipe Settings for Independent Key Transitions
DVS-9000/9000SF
3-704-674-01 (1)
Wipe Settings for Independent Key 
Transitions
You carry out independent key/downstream key transition wipe setting 
operations using the Wipe Adjust menu for each keyer.
This section describes the independent key transition wipe settings, taking the 
M/E-1>Key1>Transition>Wipe Adjust menu as an example.
Basic Procedure for Independent Key Transition Wipe 
Settings
Accessing the independent key transition wipe settings menu
As an example, to access the M/E-1>Key1>Transition>Wipe Adjust menu, 
carry out the following operation.
• In the menu control block, select the top menu selection button [M/E 1] and 
select VF1 ‘Key1’ and HF6 ‘Transition’ to display the Transition menu for 
key 1, then press [Wipe Adjust].
Carrying out the above operation displays the M/E-1>Key1>Transition>Wipe 
Adjust menu (which will be referred to below as simply the Key1 Wipe Adjust 
menu).
Selecting the independent key transition wipe pattern
You select the independent key wipe pattern from the list of patterns displayed 
in the menu.
Note 
In an independent key transition, you can only use the standard wipe patterns 
(pattern numbers 1 to 24).
To select a wipe pattern for independent key1 on the M/E-1 bank, use the 
following procedure.
1
In the Key1 Wipe Adjust menu, select [Pattern Select].
The Pattern Select menu appears.