Kolpak DA-98 Manual De Usuario

Descargar
Página de 106
Section 8 – Advanced operations
06/97 – 1.00 – 8-7
The 
REF LEVEL
 indicators [7] will light in the 
following way to show the level selected:
8.8 Meter modes
The DA-98 peak bargraph meters can be custom-
ized to suit your working preferences. Both the 
peak hold time and the “ballistics” of the meters 
can be adjusted.
8.8.1 Peak hold time
1) Enter menu group 2, move the cursor to 
Meter Mode
 and press 
ENTER
:
2) Use the 
LEFT
 and 
RIGHT
 keys to select the 
Peak Hold
 parameter and the 
UP
 and 
DOWN
 
keys to set the value for the peak signal level 
hold time.
This value can be set to values between 0 seconds 
(peak levels are not held at all) and 9 seconds. 
There is another value, 
Continue
, which will 
permanently display the maximum peak signal 
level. This can be useful if you are doing a “dry 
run” rehearsal, but you cannot keep your eyes on 
the meters all the time that the rehearsal is going 
on.
You can also use the function keys in the number 
key mode (see 5.2.2, “Using the function keys as 
number keys”) 
to enter the peak time directly.
8.8.2 Meter ballistics
Use the same menu (
Level Meter Mode
) as 
described above to change the “fall-back” ballis-
tics of the peak meters. You cannot change the rise 
time of the meters, which are fixed with peak 
meter characteristics.
1) Move the cursor to the 
Release
 parameter 
and use the 
UP
 and 
DOWN
 keys to select 
between 
Slow
Medium
 and 
Fast
.
8.9 Sine oscillator
The DA-98 incorporates a digital oscillator for 
lineup and signal tracing purposes. This oscillator 
is a sine-wave oscillator at either the standard tun-
ing frequency of 440Hz or the standard tape line-
up frequency of 1kHz.
The oscillator signal level is at the nominal signal 
level of +4dBu (but note that since the oscillator is 
a constant sine wave, it cannot truly be compared 
with “real-world” transient signals).
To operate the oscillator:
1) Enter menu 2, move the cursor to 
Sine
 
Osc.
and press 
ENTER
:
2) Use the 
UP
 and 
DOWN
 keys to turn the 
oscillator between 
off
440 Hz
 and 
1 kHz
.
When the oscillator is turned on, it overrides all 
other track inputs.
8.9.1 Recording the oscillator 
As mentioned above, the oscillator overrides all 
other track inputs, regardless of whether digital or 
analog input has been selected.
Recording the oscillator test tone is therefore sim-
ilar to any other recording operation.
Level
Indicators
-16dB
FS
16
 indicator is lit
-18dB
FS
Neither indicator is lit
-20dB
FS
20
 indicator is lit
NOTE
Any tapes produced with the TASCAM DA-88 or DA-
38 will conform to the TASCAM standard.
L e v e l
M e t e r
M o d e
P e a k
H o l d
R e l e a s e
0
s e c
F a s t
NOTE
To turn off the peak hold display if 
Continue
 
has 
been set, change the peak hold value to 
0
 seconds and 
the meter segments will “drop back”.
S i n e
O s c i l l a t o r
o f f
WARNING
When using the oscillator, you should turn down the 
monitor levels in the control room and studio to avoid 
damage to your ears (and the speakers).