Section 8 – Advanced operations  
8-8 – 1.00 – 06/97
8.10 Digital recording
The DA-98 is able to accept (and output) digital 
signals at the 
DIGITAL I/O
 connector [45] in TDIF-
1 format. The IF-88AE and IF-88SD interface 
units provide conversion to and from AES/EBU 
(and SP-DIF) and SDIF-2 formats.
The DA-98 should be connected to other TDIF-1 
equipment using a PW-88D or PW-88DL connec-
tor cable.
The DA-98 should be set to be either a word clock 
master or a word clock slave when connected to 
other digital equipment. There can only be one 
word clock master in a setup.
Since the TDIF-1 format carries a word clock as 
part of the interface, there is no need to make a 
word clock connection when recording through 
the 
DIGITAL I/O
 connector.
8.10.1 Changing between digital and 
analog inputs
To change between digital and analog inputs, sim-
ply press the 
DIGITAL IN
 switch [15]. Th
DIGITAL 
IN
 indicator will light.
8.10.2 Selecting word length
When data is accepted through the 
DIGITAL I/O
 
connector, the word length of the incoming data 
must be set. This can be selected from between 
16-bit, 20-bit or 24-bit. To set the word length:
1) Select menu 2, move the cursor to 
Word Len
and press 
ENTER
:
2) Use the 
UP
 and 
DOWN
 keys to change the value 
between 
16
20
 and 
24
 bits.
We suggest that you experiment with the dither 
settings (see 8.13, “Dither”) if you find you are 
recording quantization noise at low levels when 
the input word length is set to 20 or 24 bits. 
Though you will lose a little in the signal-to-noise 
ratio, total harmonic distortion figures will be 
improved.
8.11 Routing digital inputs
When recording analog signals, it’s usual to route 
them through a console’s sub-grouping system or 
if the number of groups is not sufficient, through 
an external patchbay. 
Neither of these is an easy option with digital sig-
nals, and so the DA-98 provides a kind of internal 
patchbay in the form of the Track Copy function 
(see 8.11.1, “Track Copy (channel-to-track rout-
ing)”)
The default setting for this feature is “straight 
through”, as shown below.
WARNING
Only use a TASCAM digital cable when making digital 
audio connections to the DA-98. Other types of cable 
may cause damage to the system, and the warranty will 
be voided if such damage is caused by use of the wrong 
cables.
NOTE
If you attempt to record digitally from a digital source 
which has a different frequency from that previously 
recorded as the DA-98’s tape format, the Fs indicator 
corresponding to the tapes sampling frequency will start 
to flash. This indicates a frequency mismatch.
Recording with different sampling frequencies is not 
recommended – problems will certainly occur on replay 
of such a recording.
T D I F
W o r d
L e n g t h
1 6
b i t
NOTE
If you are dubbing tracks from a DA-88, this value must 
always be set to 16 bits.
3 4 5 6 7 8
2
1
1 2 3 4 5 6 7 8
3 4 5 6 7 8
2
1
1 2 3 4 5 6 7 8
Track
Copy
Input
12345678
(Dig)
Tape
Track
12345678
on
Inputs
Tape
tracks