PW-6000 Installation
Setting Up the PW-6000 Hardware
Setting Up the PW-6000 Hardware
3 Setting Up the PW-6000 Hardware
The PW-6000 processor is configured with 12 jumpers and a set of 4 DIP switches.
These jumpers/switches set up the port interface, end of line termination, and
operating mode configuration. Refer to the tables below to set the jumpers as required.
These jumpers/switches set up the port interface, end of line termination, and
operating mode configuration. Refer to the tables below to set the jumpers as required.
3.1 Setting the Jumpers
Table 1 PW-6000 Jumper Settings
Jumpers
Set At
Description
J1
N/A
10Base-T/100Base-TX Ethernet Connection (Port 0)
J2
N/A
Factory Use Only
J3
OFF
Port 2 RS-485 EOL Terminator is OFF
ON
Port 2 RS-485 EOL Terminator is ON
J4
OFF
Port 3 RS-485 EOL Terminator is OFF
ON
Port 3 RS-485 EOL Terminator is ON
J5
OFF
Port 1 RS-485 EOL Terminator is OFF
ON
Port 1 RS-485 EOL Terminator is ON
J6
N/A
Factory Use Only
J7
N/A
COBOX-MICRO Ethernet Module Connection (Port 1)
J8, J9, J10
232
Port 1 is RS-232
485
Port 1 is RS-485
J11
N/A
Factory Use Only
J12
N/A
Factory Use Only