PW-6000 Installation
Setting Up the PW-6000 Hardware
PW-6000 Installation GuideDocument 800-00005, Revision A
9
3.2  Setting the DIP Switches
Dual In-line Package (DIP) switches are read when the system powers up, except 
where noted otherwise. The following table shows the setting options.
Table 2  PW-6000 DIP Switch Settings
S1
S2
S3
S4
Selection
OFF
OFF
OFF
OFF
Normal Operating Mode.
ON
OFF
OFF
OFF
When DIP switch 1 is ON, Port 0 
communicates with the web browser. 
Port 1 is used for RS-232/485 
communications. After the panel 
initialization, enable the default user 
name (admin) and password (password). 
The user name and password are read 
dynamically; you do not need to reboot 
the panel.
OFF
ON
OFF
OFF
Use the factory default communication 
parameters.
ON
ON
OFF
OFF
Unless the network administrator 
reserves an IP address for the panel 
(based on the controller board’s Media 
Access Control (MAC) address), the 
PW-6000 uses Dynamic Host 
Configuration Protocol (DHCP) to 
obtain an IP address from the network 
DHCP server. 
When power is applied with the 
switches in this position, there is a ten 
second window (when LEDs 1and 2 
flash alternately with LEDs 3 and 4), 
during which memory is cleared if 
switch 1 or switch 2 is changed to OFF. 
When switch 1 or 2 is changed to OFF, 
only LED 2 flashes and memory begins 
to be cleared. This period of clearing 
lasts several minutes. When the memory 
has been cleared, the LED pattern 
changes to the flashing of LEDs 1 and 4. 
The panel then reboots by itself. All data 
in memory is erased except the serial 
number, MAC address, hardware 
revision, and OEM code.