Ventless Hood System 
 
Installation 
 
 
Installation 
Unpacking and Handling 
Inspection for Shipping Damage 
YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates 
for damage as soon as they arrive. If damage to cartons or pallets is found, or if a shortage is found, note 
this on the bill of lading (all copies) prior to signing and receiving. 
 
If damage is found when the equipment is opened, immediately call the delivering truck line and follow up 
the call with a written report indicating concealed damage to your shipment. Ask for an immediate 
inspection of your concealed damage item. Packaging material MUST be retained to show the inspector 
from the shipping line. 
Location and Clearance 
Place the Filter Hood in a location with clearance as shown in the figure and data below. These distances 
provide for proper clearance to combustible surfaces, access for maintenance, and proper air flow from 
hood exit vent. 
 
MINIMUM CLEARANCE HOOD TO COMBUSTIBLE 
18 in. (FH-28) SIDES, 0 in. BACK, 0 in. TOP, 0 in. BOTTOM 
NON-COMBUSTABLE REAR WALL REQUIRED FOR FH-28 WALL MOUNT 
 
APPLIANCE CLEARANCE 
Vat to sides of hood: 6.25 in. (FH-28) 
Griddle to sides of hood: 0 in., Sandwich grills to sides of hood: 6 in. 
Cooking surface must be at least 3.5 inches behind the front edge of the hood. 
Appliance cabinet top or cooking surface to be level with bottom of hood sides 
± 3 in.