Bakers Pride FH-28 Manual De Usuario

Descargar
Página de 24
Ventless Hood System 
 
Installation 
 
 
11 
Securing 
Wall Mount 
After the hood has been located and leveled, secure to building by utilizing the .437 diameter holes 
provided in the rear of the fire extinguisher cylinder shelf (Refer to figure below). Using 1/4” lag screw(s), 
spacer(s) (if required), and anchor(s) (if required) secure the hood to a wall to prevent movement. The 
outside holes are spaced at 16 inches in the event wall studs can position the unit.  
 
 
Brace Mount 
If the unit is being mounted far away from a wall, a brace (angle) secured to the floor may be bolted to the 
shelf. This brace must be sufficient to prevent movement of the hood. Seal brace connection to floor 
using a food grade RTV. This will prevent grease or food particles from getting beneath the brace.