Simrad AP26 Manual De Usuario

Descargar
Página de 152
Installation 
20221586B
 67 
RATE
COMPASS
AP16, AP25, AP26
 
Figure  3-13   RC36 connection to autopilot control unit 
Plug the RC36 into a Robnet2 connector (see Figure 3-9) or cut 
the connector from the cable and connect the wires in parallel 
with the cable shown in Figure 3-11. 
3.14  RFC35 Fluxgate Compass installation 
(Optional back-up) 
The RFC35 Fluxgate Compass is a magnetic sensor, which 
means you have to take the same precautions at installation as 
for the standard RC36 (see previous page). 
•  Connect the RFC35 to the autopilot computer as per Figure 
RFC35
FLUXGATE
COMPASS
AUTOPILOT COMPUTER
MAIN PCB
Heading
Sensor
*
* NON POLARIZED
(COLOR INDEPENDENT)
HS
+
HS-
 
Figure 3-14  RFC35 connection