Installation 
20221586B
 65 
On-
O
ff
Vs
ys
+
AUTOPILOT COMPUTER
MAIN PCB
ROBNET
Bu
s+
Vs
ys
Wh
Bn
Bu
s
Pnk Gry Yel
AP26
CONTROL UNIT
REAR VIEW
TB15
 
Figure 3-11   Control unit connection 
J1 and J2 (left) are Robnet2 connectors. J3 and J4 are SimNet 
connectors. 
AP27 connection 
If a Simrad AP27 is part of the system, use the Robnet2 
connector in a free receptacle (see Figure 3-9). Alternatively cut 
the connector from the cable and connect the wires in parallel 
with the cable shown on Figure 3-11 using the same colour code. 
Note ! 
The AP27 cable contains an air-breathing tube. Check that the 
tube is open after you have cut the cable. 
3.13  RC36 Rate Compass installation 
 
Figure   3-12  
RC36 mounting 
The heading sensor is the most important part of the autopilot 
system and great care should be taken when deciding the