Simrad AP26 Manual De Usuario

Descargar
Página de 152
Simrad AP26 and AP27 Autopilots 
88
 
20221586B
 
Select STANDBY mode and enter the Installation Menu as 
previously described. Select Dockside by pressing STBD button 
and confirm by rotating the course knob clockwise. 
Boat type 
 
Actual boat type is selected by 
turning the rotary course knob. 
The options are: Planing, 
Displacement and Sail.  
Type of boat selected will affect the steering parameters, and the 
functions available in the autopilot system. Select appropriate 
Boat type and press STBD button. 
Drive unit voltage 
Set the drive unit voltage to correct level. The selections are 
12V, 24V, or 32V and should be set to the voltage specified for 
your drive unit. 
Refer to the drive unit table on page 58 for information. 
The drive engage/bypass clutch output follows the same voltage 
as set for the drive unit. It is not possible to select a higher 
voltage than the input voltage. 
Note ! 
Selection of improper voltage level for your drive unit may 
damage both the drive unit and the autopilot computer even if 
the protection circuits in the autopilot computer are activated. 
During the Rudder Test, the autopilot system will automatically 
detect whether the drive unit is a reversible motor or a solenoid 
is operated. 
To change the voltage 
selection, rotate the course 
knob. 
Note ! 
The drive unit voltage setting does not apply when operating 
solenoids on a continuous running pump/steering gear. Hence, 
the output voltage to the solenoids will be the same as the input 
voltage. 
Proceed to next menu item by pressing STBD button.