2009 Barbecue Grills and Carts
LTR20091038, Rev. A
Installation / 
Assemb
ly
www.calspas.com
5
Gas Requirements and Connection
IMPORTANT:  Cal Flame™ grills are manufactured to operate on either liquid propane (LP) or natural gas 
(NG) and cannot be converted. To verify the grill’s operating fuel, check the serial number label in the back 
of the chassis as you are looking at the grill from the front. Either LP or NG will be marked on the operating 
tab, indicating the proper operating fuel. Attempting to convert Cal Flame™ grills from one fuel to another 
may result in serious injury and will void the warranty coverage.
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the grill is 
manufactured for.
If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at 
your local hardware store.  Without it you will not be able to attach your tank to your Cal Flame™ grill or 
refill the tank at your local propane refill station.
Leak Testing Procedure
Perform a leak test at least once a year whether the 
gas  supply  cylinder  has  been  disconnected  or  not. 
In addition, whenever the gas cylinder is connected 
to  the  regulator  or  whenever  any  part  of  the  gas 
system is disconnected or replaced, perform a leak 
test.  
As a safety precaution, remember to always leak test 
your grill outdoors in a well-ventilated area.  Never 
smoke or permit sources of ignition in the area while 
doing  a  leak  test.    Do  not  use  a  flame,  such  as  a 
lighted  match  to  test  for  leaks.  Use  a  solution  of 
soapy water.
Prepare a leak testing solution of soapy water by 
1. 
mixing in a spray bottle one part liquid soap to 
one part water.
Make sure all the control knobs are in the OFF 
2. 
position.
Turn on the gas.
3. 
On 
a. 
natural gas systems, turn the main feed 
valve to the grill.
On 
b. 
LP systems, turn the cylinder valve knob 
counter clockwise one turn to open.
Apply  the  leak-testing  solution  by  spraying  it 
4. 
on  joints  of  the  gas  delivery  system.  Blowing 
bubbles in the soap solution indicates that a leak 
is present.
Stop a leak by tightening the loose joint or by 
5. 
replacing  the  faulty  part  with  a  replacement 
part  recommended  by  the  manufacturer.  Do 
not  attempt  to  repair  the  cylinder  valve  if  it  is 
damaged. The cylinder must be replaced.
Turn  all  control  knobs  back  to  the  full  OFF 
6. 
position.
If you are unable to stop a leak:
Turn  all  control  knobs  back  to  the  full  OFF 
1. 
position.
 Shut off the gas supply to the grill and release 
2. 
pressure in the hose and manifold by pushing in 
and turning any of the control valves one quarter 
turn counter-clockwise.
 On LP systems,  remove the cylinder from the 
3. 
grill.
Call  an  authorized  gas  appliance  service 
4. 
technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.