Cal Flame Barbecue Grills & Carts Manual De Usuario

Descargar
Página de 28
2009 Barbecue Grills and Carts
LTR20091038, Rev. A
Installation / 
Assemb
ly
www.calspas.com
7
Natural Gas
Requirements
Always check the rating plate to make sure the gas 
supply you are hooking up to is the gas type the grill 
is manufactured for.
IMPORTANT: Never connect the grill to an unregulated 
gas supply.
The  installation  of  this  appliance  must  conform 
with  local  codes  or,  in  the  absence  of  local  codes, 
to  the  national  fuel  gas  code,  ANSI  Z223.1a-1998. 
Installation  in  Canada  must  be  in  accordance  with 
the standard CAN/CGA-B149.2, Propane Installation 
Code.
A  licensed  contractor  or  local  gas  company 
representative  must  perform  all  natural  gas 
connections.
Ensure  that  the  service  supplying  the  grill  is  fitted 
with a shut off valve conveniently positioned near the 
grill and giving ease of access.
The grill must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 0.5 psi 
(3.5 kPa).
The  grill  and  its  individual  shutoff  valve  must  be 
disconnected  from  the  gas  supply  piping  system 
during  any  pressure  testing  of  that  system  at  test 
pressure in excess of 0.5 psi (3.5 kPa).
Your Cal Flame™ grill for use with natural gas comes 
equipped  with  its  own  regulator  that  MUST  NOT 
be removed. If, this regulator needs to be replaced 
use  only  the  type  specified  by  Cal  Flame™  for  this 
appliance.
Connection
Remove  the  rear  panel  from  the  barbecue  to 
1. 
gain access to the regulator and gas connection 
point.
Connect  a  suitable  flex  connector  to  the  grill 
2. 
regulator.
Check the grill controls to ensure all control valves 
3. 
are in the full OFF position.
Turn  on  the  main  gas  supply  and  check  all 
4. 
connections  for  leaks  using  soapy  water  as 
described in the leak testing procedure section.
Warning: If you see bubbles in the soapy solution at 
any of the connections, turn off the gas supply and 
tighten the connection. If tightening the connection 
does not seal the leak, it may be necessary to replace 
the flex hose.