KitchenAid 36-Inch 5 Burner Gas Cooktop, Architect® Series II Guía De Instalación

Descargar
Página de 24
7
Gas Pressure Regulator
The gas pressure regulator supplied with this cooktop must be 
used. The inlet pressure to the regulator should be as follows for 
proper operation:
Natural Gas:
Minimum pressure: 5" (12.7 cm) WCP
Maximum pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP
LP Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.
Burner Input Requirements
Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m). 
For elevations above 2,000 ft (609.6 m), ratings are reduced at a 
rate of 4% for each 1,000 ft (304.8 m) above sea level (not 
applicable for Canada). 
For elevations above 6,560 ft (1999.5 m) a high altitude kit is 
needed to avoid any reduced power output. See separate LP gas 
conversion instructions sheet.
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure shown on 
the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping system 
by closing its individual manual shutoff valve during any pressure 
testing of the gas supply piping system at test pressures equal to 
or less than ½ psi (3.5 kPa).
INSTALLATION INSTRUCTIONS
Install Cooktop
Style 1: Cooktop over undercounter built-in oven
IMPORTANT: Clamping brackets should not be used.
1. Using 2 or more people, place cooktop right side up into the 
cutout.
NOTE: Make sure that the front edge of the cooktop is 
parallel to the front edge of the countertop. If repositioning is 
needed, lift entire cooktop up from cutout to avoid scratching 
the countertop.
Style 2: Cooktop over cabinets
1. Determine whether your cabinet construction provides 
clearance for installing clamping brackets at cooktop base 
ends. This is the recommended location. Clamping brackets 
can be installed on the front and back of cooktop base 
bottom, if necessary. 
2. The clamping brackets can be installed before or after the 
cooktop is placed into the cutout. Complete the following 
steps for the option you choose.
A. Attachment screw holes for optional front and back 
location.
B. Clamping bracket (end locations recommended)
C. Cooktop base bottom
D. Attachment screw
E. Attachment screw location (recommended)
WARNING
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
A
B
C
D
E