Honeywell TL8100 Guía De Instalación

Descargar
Página de 12
TL8100
69-2017EFS—03
2
THERMOSTAT WIRING
Fig. 3. Wiring diagram for a line voltage circulator.
Fig. 4. Wiring diagram for a line voltage electric heater.
Fig. 5. Wiring diagram for a line voltage valve (V4043 or 
similar).
Fig. 6. Wiring diagram for a line voltage 3-wire valve 
(V4044 or equivalent); V8044 may be used with 24 VAC 
power.
Fig. 7. Wiring diagram for a 24 VAC 2-wire valve 
(V8043A,E or equivalent).
Fig. 8. Wiring diagram for a 24 VAC V8043F.
Fig. 9. Wiring diagram for a White Rogers 1311 valve.
Fig. 10. Wiring diagram for a 24 VAC furnace or hydronic 
zone panel.
Remote Input Wiring
The thermostat has an input for connecting a home 
automation system or a remote control system. When a 
signal is received at this input, the thermostat switches to 
Vacation mode. When the signal is removed, the 
thermostat returns to the original mode. See Fig. 11.
Fig. 11. Wiring for a home automation system.
1
3
M29965
L
L
N
120 VAC OR 240 VAC
2 AMP MAXIMUM INDUCTIVE LOAD
2
TL8100
1
3
M29966
L
G
G
N 120/240 VAC
5 AMP MAXIMUM RESISTIVE LOAD
L
N
ELECTRIC HEATER
2
TL8100
1
3
M29967
L
N
120/240 VAC
2 AMP MAXIMUM INDUCTIVE LOAD
2
V4043
L
N
TL8100
1
3
2
M29968
RED
BLUE
YELLOW
MOTOR
V4044 OR V8044
VALVE OPERATOR
L
N
TL8100
1
3
M29977
C
R
2
V8043A, E
L
N
CONNECT BLACK WIRES ON V8043A AND 
YELLOW WIRES ON V8043E.
1
1
TL8100
1
3
M29978
C
R
2
V8043F
L
N
TH, TR TH TR
TL8100
1
3
2
TL8100
2
5
4
6
1
3
1311
C
R
M29970
L
N
M29971
W
R
FURNACE OR 
T, T ON PANEL
1
3
2
TL8100
TL8100
HOME AUTOMATION
SYSTEM
12 VDC
± 10%
M29972