69-2017EFS—03
THERMOSTAT CONFIGURATION
Table 1 shows the configuration of the switches on the 
back of the front module. Default settings are inside the 
shaded cells.
Temperature Control Mode
Choose proportional adaptive mode by placing switch #5 
in the up position for these types of systems.
• Hot water heat systems
• Gas, oil, or electric furnaces
• Electric radiant or convection heating
See Table 2 to set switches #1 and #2 for how to configure 
proportional adaptive mode.
Choose conventional mode by placing switch #5 in the 
down position for these types of systems:
• Gas or oil furnace or boiler with a 30-second or longer 
combustion gas prepurge cycle. To figure out the gas 
purging cycle of your system, measure the time lapse 
from the instant the thermostat sends the heating 
command to the instant the burner actually goes on.
• Systems where the user desires to set how many 
degrees the air temperature must fall before the 
thermostat calls for heat. In general, the slower the 
HVAC system is able to distribute heat, the smaller the 
the differential should be.
• When more than one TL8100 is wired directly to one 
zone valve or one zone circulator.
See Table 3 to set switches #1 and #2 for how to configure 
conventional mode.
POWER-UP
When you install the batteries, the unit 
performs a series of tests for a few 
seconds before displaying the ambient 
temperature.
It is normal that the displayed temperature 
be higher than the ambient temperature if 
you are holding the thermostat. Once 
installed on the wall, the thermostat will 
display the true ambient temperature after 
one hour.
Table 1. 
Switches
Description
Up
Down
1 & 2
Cycle length
(proportional)
Deadband
(conventional)
See Table 2 and 3.
3
Clock display
12H
24H
4
Temperature 
display
a
a
Every time you change the temperature display format, 
the comfort and economy preset temperatures return to 
their default settings.
°F
°C
5
Temperature
control mode
Proportional 
Mode (see 
Conventional 
Mode (see 
6
Pump 
protection 
b
b
For hot water installations, it is recommended to enable  
this function to activate the pump for one minute every 
24 hours to prevent pump seizure.
Deactivate
Activate
Table 2. Proportional Mode.
Cycle 
length
Heating Type
Position
5 minutes 
(12 CPH)
For faster cycling systems
10 minutes 
(6 CPH)
Fossil fuel or electric wall furnaces, 
electric forced air, electric radiant or 
convection heating
15 minutes 
(4 CPH)
Standard efficiency fossil fuel forced air 
systems or high temperature, fast 
response, hot water systems
20 minutes 
(3 CPH)
High efficiency fossil fuel systems or 
slow response hot water systems
Table 3. Conventional Mode.
Differential
Position
0.5 °F (0.3 °C)
0.7 °F (0.4 °C)
0.9 °F (0.5 °C)
1.1 °F (0.6 °C)