fisher--paykel dd605 Manual De Usuario

Descargar
Página de 39
599464 
 
16
4.3 
Fast Test Cycle 
Press and hold KEYLOCK, then START/PAUSE for 5 seconds. 
All LEDs & LCD segments except Keylock are illuminated. 
Press POWER twice. 
“FC” will show in the display (integrated and flat door models: Heavy, 
Normal, Delicate, Rinse LEDs showing). 
Press START/PAUSE twice. 
The 8 minute fast test cycle will start. 
Press POWER to exit. 
4.4 
Continuous Cycle 
Press and hold KEYLOCK, then START/PAUSE for 5 seconds. 
All LEDs & LCD segments except Keylock are illuminated. 
Press POWER three times. 
“CC” will show in the display (integrated and flat door models: Heavy, 
Normal, Rinse LEDs showing). 
Press START/PAUSE. 
The last cycle that had been selected prior to going into diagnostics mode 
will be run continuously. 
Press POWER to exit. 
4.5 
Temperature & Voltage Display Mode 
(Not available on integrated or flat door models.) 
Start a wash cycle running. 
Press & hold KEYLOCK for 4 seconds. 
Keylock will be activated. 
Press & hold START/PAUSE for 8 seconds. 
LCD will now alternate between 
°C symbol and the water temperature. 
Press START/PAUSE. 
LCD will now alternate between 
°E symbol and the controller’s rail voltage. 
Press & hold KEYLOCK for 4 seconds. 
Keylock is deactivated. 
Press POWER to exit.