Graco Inc. CED1 Manual De Usuario
Operation
3A0245A
7
Operation
FCC Notice (FCC ID: JHICED1)
Model Number: DFS150
Model Number: DFS150
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
Operation is subject to the following two conditions:
•
This device may not cause harmful interference.
•
This device must accept any interference that may
be received, including interference that may cause
undesired operation.
be received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by
Graco, Inc. could void the user's authority to operate this
equipment.
Graco, Inc. could void the user's authority to operate this
equipment.
IC Notice (IC: 4840ACED1)
This product meets the applicable Industry Canada
technical specifications/Le présent materiel est con-
forme aux specifications techniques applicables
d’Industrie Canada.
technical specifications/Le présent materiel est con-
forme aux specifications techniques applicables
d’Industrie Canada.
Setup
1.
Connect pump module to hopper and cart. Tighten
knob on front of pump module and clamp other end
to hopper.
knob on front of pump module and clamp other end
to hopper.
2.
Connect power cord. Turn ON/OFF to OFF.
3.
Connect material hose to outlet.
NOTE: Up to 150 ft of 1/2 in. hose plus 15 ft. x 1/4
in. can be connected to the unit. If desired flow rate
is not obtainable, reduce hose length or add addi-
tional water to mud mixture.
NOTE: Up to 150 ft of 1/2 in. hose plus 15 ft. x 1/4
in. can be connected to the unit. If desired flow rate
is not obtainable, reduce hose length or add addi-
tional water to mud mixture.
4.
Select 15A/20A setting based on your circuit rating.
5.
Connect Z swivel.
6.
Connect selected finishing tool to Z swivel using
supplied sanitary clamps.
supplied sanitary clamps.
“Learn” the Valve
This unit performs differently depending on which valve
is being used. Each time you change valves, perform
the following steps so the unit can “Learn” the valve.
is being used. Each time you change valves, perform
the following steps so the unit can “Learn” the valve.
1.
Turn flow control knob down (but not OFF).
2.
Push digital display button 3 times until LEARN
appears on display screen.
appears on display screen.
3.
Pull trigger on valve.
4.
OK should then appear on display screen (if not,
see Troubleshooting).
see Troubleshooting).
GROUNDING INSTRUCTIONS
This appliance is rated more than 15 A and is for use
on a circuit having a nominal rating of 120 V and is fac-
tory equipped with a specific electric cord and plug. No
adapter should be used with this appliance. If the appli-
ance must be reconnected for use on a different type of
electric circuit, the reconnection should be made by
qualified service personnel; and after the reconnection,
the appliance should comply with all local codes and
ordinances.
This appliance is rated more than 15 A and is for use
on a circuit having a nominal rating of 120 V and is fac-
tory equipped with a specific electric cord and plug. No
adapter should be used with this appliance. If the appli-
ance must be reconnected for use on a different type of
electric circuit, the reconnection should be made by
qualified service personnel; and after the reconnection,
the appliance should comply with all local codes and
ordinances.
Consult a qualified electrician if there is any doubt as to
whether an outlet box is properly grounded.
whether an outlet box is properly grounded.
Do NOT tamper with relief valve or devices that control
maximum pressure control during normal operation.
Bodily injury and/or damaged to equipment can occur.
maximum pressure control during normal operation.
Bodily injury and/or damaged to equipment can occur.
ti11679a
ti11678a
ti11673a
ti4265a
ti2810a
ti4265a