3-1
SECTION III
OPERATION
3-1.
INTRODUCTION.
3-2.
This section identifies all controls and indicators associated with the AM-2.5E/AM-5E
transmitters and provides standard operating procedures.
3-3.
CONTROLS AND INDICATORS.
3-4.
Figures 3-1, 3-2, and 3-3 present the location of all controls and indicators associated with
normal operation of the AM-2.5E and AM-5E transmitters. Tables 3-1, 3-2, and 3-3
present the functions of each control or indicator. Refer to Figures 3-1 through 3-3 and
Tables 3-1 through 3-3 for a description of the controls and indicators associated with the
AM-2.5E/AM-5E transmitters.
TABLE 3-1. AM-2.5E/AM-5E CONTROLS AND INDICATORS
(Sheet 1 of 2)
INDEX
NO.
NOMENCLATURE
FUNCTION
1
FORWARD POWER
Displays the transmitter forward power output in
Meter
watts as selected by the FORWARD POWER Meter
LOW/HIGH/OFF switch.
2
FORWARD POWER
Configures the FORWARD POWER meter: 1) to
Meter HIGH/LOW/OFF
display forward power information on the HIGH
Switch
scale, 2) to display forward power information on the
LOW scale, or 3) to off. In the AM-2.5E: 1) the HIGH
scale is from 0 to 3000 watts and 2) the LOW scale is
from 0 to 750 watts. In the AM-5E: 1) the HIGH
scale is from 0 to 6000 watts and 2) the LOW scale is
from 0 to 1500 watts.
3
REFLECTED POWER
Displays the transmitter reflected power output in
Meter
watts or the ac input voltage in volts as selected by
the REFLECTED POWER HIGH/LOW/VAC
Switch.
4
REFLECTED POWER
Configures the REFLECTED POWER meter to
Meter HIGH/LOW/VAC
display: 1) reflected power information on the HIGH
Switch
scale, 2) reflected power information on the LOW
scale, or 3) the ac input voltage. In the AM-2.5E:
1) the HIGH scale is from 0 to 300 watts and 2) the
LOW scale is from 0 to 60 watts. In the AM-5E:
1) the HIGH scale is from 0 to 600 watts and 2) the
LOW scale is from 0 to 150 watts. The ac volts scale is
from 150 to 300 volts.