Cumberland Stove Works MF3800 Manual De Usuario

Descargar
Página de 32
INSTALLATION AND OPERATION MANUAL
MF3700, MF3800 Models
Page 8
800-345-6007
CumberlandStoveWorks.com
SPECIFICATIONS
Model Number
MF3700, MF3800
BTU/hour input (1)
45,000 max
Heating Capacity (2)
1,200 Sq. Ft. 
Electrical Rating (3)
110 Volts, 15 Amp, 
60 Hz
Power Consumption
Controller = 2.0 Watts
Stove = 200 Watts
Fuel Storage Capacity
62 lbs.
Flue Size (4)
3 in.
Width
22 in.
Height
40 in.
Depth
22 in.
Weight
287 lbs.
(1)  Heat  output  will  vary,  depending  on  the  brand,  type
and quality of fuel and the moisture content. Consult your 
dealer for best results. 
(2) Based on post 1982 home construction, requiring 35
BTU/Hr. per Sq. Ft.
(3) Install per NFPA 70 and follow all state and local codes,
contact licensed electrical contractor for assistance.
(4) Install per NFPA 211 and follow all state and local codes,
contact licensed installers for assistance.
Listing label:
 
Tested to the following stardards: UL1482, ASTM E1509,
ULC/ORD-C1482-M1990
GLASS SPECIFICATIONS
This stove is equipped with 5mm ceramic glass. Replace 
 CAUTION
THIS  INSTALLATION  MUST  CONFORM  WITH  LOCAL 
CODES. IN THE ABSENCE OF LOCAL CODES YOU MUST 
COMPLY WITH ASTM E509, (UM) 84-HUD, ULC/ORD-
C-48.
CUMBERLAND STOVE WORkS, MANUFACTURER OF 
THIS APPLIANCE, RESERVES THE RIGHT TO ALTER ITS 
PRODUCTS, THEIR SPECIFICATIONS AND/OR PRICE 
WITHOUT NOTICE.