Cumberland Stove Works MF3800 Manual De Usuario

Descargar
Página de 32
INSTALLATION AND OPERATION MANUAL
MF3700, MF3800 Models
Page 
800-345-6007
CumberlandStoveWorks.com
PARLOR STOVE FLOOR PAD CLEARANCES
INSTALLATION
It is recommended the stove be installed and serviced by 
authorized professionals who are certified by the National
Fireplace Institute (NFI) as NFI Pellet Specialists.
Proper installation of this stove is necessary for safe and 
efficient operation. Installing this product improperly may
result in a house fire and personal injury. All applicable
building  codes  for  your  location  must  be  followed.  In 
areas  where  building  codes  require  additional  steps  to 
the installation of this product not included in this manual, 
the  building  codes  will  take  precedent  and  must  be 
followed.  Contact your local building inspector to obtain 
any  necessary  permits  or  inspection  guidelines  before 
installing the product.
STOVE PLACEMENT
Sketch out a plan for installing the stove including dimensions 
before  permanent  placement.  When  determining  the 
location for the stove, wall stud location is critical. You may 
need to adjust the location of the stove to avoid trying to 
vent through a wall stud. Before placing the parlor stove, 
connect  the  vent  and  allow  for  minimum  clearance  to 
combustible walls. 
FLOOR PROTECTION REqUIREMENTS
The  stove  must  be  installed  on  a  noncombustible  floor,
with proper floor protection, or on a masonry hearth. The
hearth  or  noncombustible  floor  protector  must  extend  a
minimum of 6” in front, and 4” from each side. When a
clean out t-vent is installed in the inside of a home, the
floor protector must extend 2” beyond rear of t-vent. See
figure 12. When stove is vented straight through the wall
and the clean out t-vent is on the exterior of the home, the
minimum clearance is 3” from the back of the stove to the
edge of floor protector. See figure 13. The minimum floor
protector material is 24 gA. sheet metal.
 WARNING
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL 
AND  USE  THIS  STOVE.  FAILURE  TO  FOLLOW  THE 
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, 
BODILY INJURY, OR EVEN DEATH.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 
VENTING SYSTEM OF THIS UNIT.
DO  NOT  CONNECT  THIS  UNIT  TO  A  CHIMNEY  FLUE 
SERVING ANOTHER APPLIANCE.
CHILDREN  AND  ADULTS  SHOULD  BE  ALERTED  TO 
THE HAZARDS OF HIGH SURFACE TEMPERATURES 
AND SHOULD STAY AWAY TO AVOID BUMPS TO SkIN 
AND/OR CLOTHING.
YOUNG  CHILDREN  SHOULD  BE  CAREFULLY 
SUPERVISED WHEN THEY ARE IN THE SAME ROOM 
AS THE STOVE.
CLOTHING  AND  OTHER  FLAMMABLE  MATERIALS 
SHOULD NOT BE PLACED ON OR NEAR THIS UNIT.
 CAUTION
THIS  STOVE  SHOULD  NOT  BE  USED  AS  THE  ONLY 
SOURCE OF HEAT IN THE HOUSE. POWER OUTAGES 
AND  PERIODIC  MAINTENANCE  WILL  RESULT  IN  A 
TOTAL LOSS OF HEAT.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT 
RESTRICTIONS  AND  INSTALLATION  INSPECTION 
REqUIREMENTS IN YOUR AREA.
CONTACT  YOUR  LOCAL  AUTHORITY  (SUCH  AS 
MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, 
FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE 
NEED FOR A PERMIT.
kEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS, 
LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE 
OUTLET ON THE OUTSIDE OF THE BUILDING.
INSTALLATION AND REPAIR OF THIS PARLOR STOVE 
SHOULD BE DONE BY A qUALIFIED SERVICE PERSON. 
THE  APPLIANCE  SHOULD  BE  INSPECTED  BEFORE 
USE  AND  AT  LEAST  ANNUALLY  BY  A  qUALIFIED 
SERVICE PERSON. IT IS IMPERATIVE THAT CONTROL 
COMPARTMENTS, FIRE BOX, AND CIRCULATING AIR 
PASSAGEWAYS OF THE STOVE BE kEPT CLEAN. 
4”
4”
6”
2”
Figure 12
Figure 13
4”
4”
6”
3”