Operation 
14
3A0591U
Operation
Pressure Relief Procedure
NOTE: Do not close the main air valve until Step 6. The 
Enclosed Air Controls will not operate when the main air 
supply is in the Off position.
1.
Enclosed Air Controls: See F
. 3. Turn the air 
motor switch (BF) to off. 
Exposed Air Controls: See F
. 3. Close the air 
motor slider valve (BF).
2.
Back the ram director air regulator down to zero. Set 
the ram director switch/valve (BC) to DOWN. The 
ram will slowly drop.
3.
Jog the director valve up and down to bleed air from 
ram cylinders.
4.
Turn the inflatable seal switch (BJ) to off.
5.
Open the fluid ball valve and/or dispensing valve to 
relieve fluid pressure.
6.
Close the main air valve (BA).
Flush Before First Use
The sanitary pump was assembled using sanitary lubri-
cant on moving parts and was tested in water. Flush the 
pump thoroughly with an appropriate cleaning solution 
or disassemble and sanitize the parts before using the 
pump. See your separate pump manual for complete 
flushing and cleaning procedures for a sanitary pump. 
Check national, state, and local codes for specific
limitations.
Setting Inflatable Seal Pressure
1.
Set an empty drum on the ram base. Set the direc-
tor valve (BC) to DOWN. Lower the seal into the 
drum to the point of the drum’s largest inside diame-
ter.
2.
Set the inflatable seal switch (BJ) to On. Adjust the 
seal air regulator until the seal just touches the 
inside of the drum.
3.
Leave regulator set at this setting for this style of 
drum.
4.
Set the inflatable seal switch to Off to deflate seal 
before raising the ram. Set the director valve (BC) to 
UP and let the ram rise to its full height.
5.
Remove the empty drum.
NOTE: Use the lowest seal pressure possible to achieve 
desired results. Excessive seal pressure may cause the 
seal to roll off of the follower plate. To prevent overpres-
surization, a relief valve limits seal pressure to 30 psi 
(2.1 bar, 0.21 MPa).
Trapped air can cause the pump to cycle 
unexpectedly, which could result in serious injury 
from injection, splashing or moving parts. Relieve 
pressure when you stop pumping and before 
cleaning, checking, or servicing equipment.