Operation
3A0591U
15
Starting and Adjusting the Ram
1.
Close all air regulators and air valves.
2.
Turn on the main air supply.
3.
Open the main air valve (BA), and set the ram direc-
tor air regulator (BB) to 2.8 bar, 0.26 MPa (40 psi). 
Set the director valve (BC) to UP and let the ram 
rise to its full height.
4.
Lubricate inflatable seal (C) with sanitary lubricant.
5.
Set a full drum of fluid on the ram base, slide it back 
against the tube stop, and center it under the fol-
lower plate. 
6.
Remove the drum cover, and smooth the surface of 
the fluid with a straightedge.
7.
Secure the bag liner to the drum with tape or a 
strap, to prevent it from sliding into the drum.
8.
Set the director valve to DOWN. Set ram air regula-
tor at about 40 psi (0.28 MPa, 2.8 bar). Lower the 
ram until the ram plate is about to enter the drum, 
and set the valve to neutral. Reposition the drum as 
necessary so the inflatable seal does not hit the 
drum lip.
NOTE: Enclosed Controls: To increase or decrease 
the speed of downward travel on the ram plate, adjust 
the valve on the muffler (BN) inside the control box. See 
F
. 4, page 16.
Exposed Controls: To increase or decrease the speed 
of downward travel on the ram plate, adjust the director 
valve (BC).
9.
Set the director valve to DOWN, and continue to 
lower the ram until the ram plate contacts the fluid.
10. Set seal air pressure regulator to pressure deter-
mined in Setting Inflatable Seal Pressure, page 
14. Set the inflatable seal switch to On to inflate 
seal.
NOTE: If fluid leaks past the seal, increase the air pres-
sure to the seal gradually until leaking stops. To prevent 
overpressurization, a relief valve limits seal pressure to 
30 psi (2.1 bar, 0.21 MPa).
• Do not inflate the seal when not installed on the 
follower plate. Wear safety glasses when 
operating the seal. Seal burst could result in 
injury.
• Keep hands and fingers away from the ram plate, 
pump fluid inlet, and lip of the fluid container 
when raising or lowering the ram to reduce risk of 
serious injury from moving parts.
NOTICE
Do not use drums that have side bungs or large dents 
with this ram. Rough bung openings or large dents will 
damage the inflatable seal or stop the ram plate, result-
ing in a runaway pump.