Calibration Check
3A2894F
49
Calibration Check
Perform the calibration check procedure to verify the cal-
ibration of the flow meters are correct.
ibration of the flow meters are correct.
1.
Perform Base Purge, page 44.
2.
Navigate to the Home screen.
3.
Activate
on the DM.
4.
Remove the static mixer.
5.
MD2 Only: Install the calibration nozzle onto the
dispense applicator.
dispense applicator.
6.
Open the catalyst (B) ball valve located near the dis-
pense applicator.
pense applicator.