Graco 332235A - Direct Immersion Kit 16U764 for 2570ES Manual De Usuario

Descargar
Página de 14
332235A
5
Removing Hydraulic Head and Pump
1.
Follow Pressure Relief Procedure, page 4.
2.
Allow unit to cool. 
3.
Remove two hydraulic lines from head and body.
4.
Remove suction set from pump.
5.
Remove four mounting bolts on pump assembly and 
set assembly out of the way.
6.
Remove two black plugs.
NOTE: Protect open hydraulic ports from debris and 
contamination.
BURN HAZARD 
Equipment surfaces and fluid that’s heated can 
become very hot during operation. To avoid severe 
burns, do not touch hot fluid or equipment. Wait until 
equipment/fluid has cooled completely.
hydraulic
ti20953a
lines
suction
set
pump
ti21180a
bolts
pump
assembly
ti7598a
ti21178a
hydraulic
ports
plugs