6
332235A
Installing Direct Immersion Kit
1.
Install tower/bracket into frame holes.
2.
Install four retaining screws in frame to hold 
tower/bracket in place. Torque to 165 +/- 10 in-lb 
(13.8 ft-lb).
3.
Install four bolts onto immersion kit. 
4.
Install pump assembly over four frame bolts. 
5.
Torque bolts to 400 +/- 10 in-lb (33.3 ft-lb).
6.
Install new, longer hydraulic lines (19, 20) from kit.
7.
To purge air from hydraulic lines, increase pressure 
enough to start hydraulic motor stroking and allow 
fluid to circulate for 15 seconds. Turn pressure 
down, turn Prime valve horizontal (off).
Pumping motion could result in bracket pulling out of 
frame and cause serious injury. Always insert and 
torque screws securely to insure this does not occur.
tower
bracket
frame
holes
ti7600b
ti7601b
ti20994a
pump
assembly
ti7602b
ti7603b
19
20
ti7604b
+
-
ti7110c
ti7111b
ti7129b