Avoid direct contact with the circ u i t ry to prevent electrostatic discharge (ESD).
NEVER transmit without an antenna attached to the transmitter.
Ensure proper data pin connections.
During normal paging operations, position the paging transmitter antenna 
vertically to maximize paging range.  When using a transmitter in the shelf 
mount configuration, use a right angle coaxial antenna adapter for proper
antenna positioning.  
Install the APSXMTR unit as a wall-mount unit or in some other secure
location.
Right angle brackets and screws are provided for wall mounting.
2.4
C on n e c t i ng   t h e   Un i t
The physical components of the system include:
APS Custom unit
Transmitter
Antenna
DB9 Null Modem Cable
DB9 Cable to Flying Leads
DB9 to DB25 Modem Cable
To connect the unit, follow the steps below.
1. Connect the telephone line inputs.  Line 1 is for Port 1 and must be connected
correctly to ensure successful system operation.  Line 2 is for Port 2 used as 
the second call handling port in higher traffic. Line 3 is for the outbound 
port, Port 3, used for wide area and/or overhead paging.
NOTE:  To ensure proper operation of the unit, the physical line connections 
must match the information specified in the PCI database.
2. Connect the data cables to the unit and transmitter.  The power LED on the 
unit will be lit.
3. Optionally, connect one or more of the contact closure port pins to external 
dry contact closure type switches. Please refer to the contact closure port pin
specification for proper connection (Figure 2-1). A closure between any contact 
pin (1-8) and Common (pin 9) will cause that event to activate.  For more 
detailed information on contact closures, refer to section 3.2.5, Configuring 
Contact Closure Event Scripts
.