Safety Codes and Standards
This appliance complies with one or more of the following
standards:
standards:
•
UL 858, Household Electric Ranges
•
CAN/CSA-C22.2 No. 61 Household Cooking
Ranges
Ranges
•
ANSI Z21.1b-2012 Household Cooking Gas
Appliances
Appliances
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific locations.
determine if additional requirements and/or standards
apply to specific locations.
Installation Clearances
(see Figure at right)
From the cooking surface to materials above:
•
•
There must be a minimum clearance of 36” (91.4 mm)
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.
•
The minimum clearance from the top of the cooking
surface to a vent hood, or an over-the-range
microwave hood is 30” (762 mm).
surface to a vent hood, or an over-the-range
microwave hood is 30” (762 mm).
•
A 24” (610 mm) clearance is acceptable when the
bottom of the wood or metal cabinet is protected by not
less than 1/4” (6 mm) of a flame retardant material
covered with not less than No. 28 MSG sheet steel,
0.015” (0.38 mm) thick stainless steel, 0.024”
(0.61 mm) aluminum, or 0.02” (0.51 mm) thick copper.
less than 1/4” (6 mm) of a flame retardant material
covered with not less than No. 28 MSG sheet steel,
0.015” (0.38 mm) thick stainless steel, 0.024”
(0.61 mm) aluminum, or 0.02” (0.51 mm) thick copper.
From the cooking surface to side materials:
•
•
No clearance is required from the unit walls to the
adjacent vertical combustible walls on rear, right, or
left.
adjacent vertical combustible walls on rear, right, or
left.
•
Clearance from cooking surface to adjacent vertical
walls must be at least 9” (229 mm).
walls must be at least 9” (229 mm).
Flame retardant materials bear the mark:
UNDERWRITERS LABORATORIES INC. CLASSIFIED
MINERAL AND FIBER BOARDS SURFACE BURNING
CHARACTERISTICS, followed by the flame spread and
smoke ratings. These designations are shown as “FHC
(FIame Spread/Smoke Developed).” Materials with “O”
flame spread ratings are flame retardant. Local codes may
allow other flame spread ratings. It is the responsibility of
the installer to ensure installation is in accordance with
these ratings.
UNDERWRITERS LABORATORIES INC. CLASSIFIED
MINERAL AND FIBER BOARDS SURFACE BURNING
CHARACTERISTICS, followed by the flame spread and
smoke ratings. These designations are shown as “FHC
(FIame Spread/Smoke Developed).” Materials with “O”
flame spread ratings are flame retardant. Local codes may
allow other flame spread ratings. It is the responsibility of
the installer to ensure installation is in accordance with
these ratings.
36
36
36” (914 mm) if
contains combustible
materials
contains combustible
materials
36” (914 mm) if
contains combustible
materials
contains combustible
materials
36” (914 mm) if
contains combustible
materials
contains combustible
materials
Cooking
Surface
Surface
Cooking
Surface
Surface
Cooking
Surface
Surface
Range Width
Range Width
Range Width
30” (762 mm)
30” (762 mm)
30” (762 mm)
9” (229 mm)
9” (229 mm)
9” (229 mm)
min. to combustible
min. to combustible
min. to combustible
sidewall material
sidewall material
sidewall material
(both sides)
(both sides)
(both sides)
As defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12” (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
scope and are not certified by CSA. Clearances of less than 12” (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
p
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area above countertop
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area above countertop
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area above countertop
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area above countertop
indicates minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.