5 -  44 
5. PARAMETERS 
 
5.4 I/O setting parameters (No.PD
POINT 
 
For any parameter whose symbol is preceded by *, set the parameter value and 
switch power off once, then switch it on again to make that parameter setting 
valid. 
 
 
5.4.1 Parameter list 
No. Symbol 
Name 
Initial 
value
Unit 
Control mode 
Position Speed  Torque
PD01  *DIA1  Input signal automatic ON selection 1 
0000h 
 
 
 
 
PD02 
 
For manufacturer setting 
0000h 
 
 
 
 
PD03 
*DI1 
Input signal device selection 1 (CN1-15) 
00020202h
 
 
 
 
PD04 
*DI2 
Input signal device selection 2 (CN1-16) 
00212100h
 
 
 
 
PD05 
*DI3 
Input signal device selection 3 (CN1-17) 
00070704h
 
 
 
 
PD06 
*DI4 
Input signal device selection 4 (CN1-18) 
00080805h
 
 
 
 
PD07 
*DI5 
Input signal device selection 5 (CN1-19) 
00030303h
 
 
 
 
PD08 
*DI6 
Input signal device selection 6 (CN1-41) 
00202006h
 
 
 
 
PD09 
 
For manufacturer setting 
00000000h
 
 
 
 
PD10 
*DI8 
Input signal device selection 8 (CN1-43) 
00000A0Ah
 
 
 
 
PD11 
*DI9 
Input signal device selection 9 (CN1-44) 
00000B0Bh
 
 
 
 
PD12  *DI10  Input signal device selection 10 (CN1-45) 
00232323h
 
 
 
 
PD13 
*DO1  Output signal device selection 1 (CN1-22) 
0004h 
 
 
 
 
PD14 
*DO2  Output signal device selection 2 (CN1-23) 
000Ch 
 
 
 
 
PD15 
*DO3  Output signal device selection 3 (CN1-24) 
0004h 
 
 
 
 
PD16 
*DO4  Output signal device selection 4 (CN1-25) 
0007h 
 
 
 
 
PD17 
 
For manufacturer setting 
0003h 
 
 
 
 
PD18 
*DO6  Output signal device selection 6 (CN1-49) 
0002h 
 
 
 
 
PD19 
*DIF 
Input filter setting 
0002h 
 
 
 
 
PD20  *DOP1  Function selection D-1 
0000h 
 
 
 
 
PD21 
 
For manufacturer setting 
0000h 
 
 
 
 
PD22  *DOP3  Function selection D-3 
0000h 
 
 
 
 
PD23 
 
For manufacturer setting 
0000h 
 
 
 
 
PD24  *DOP5  Function selection D-5 
0000h 
 
 
 
 
PD25 
 
For manufacturer setting 
0000h 
 
 
 
 
PD26  
0000h 
PD27  
0000h 
PD28  
0000h 
PD29  
0000h 
PD30  
0000h