Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
6 -  2 
6. DISPLAY AND OPERATION SECTIONS 
 
6.2 Display sequence 
Press the "MODE" button once to shift to the next display mode. Refer to section 6.3 and later for the 
description of the corresponding display mode. 
To refer to or set the gain filter parameters, extension setting parameters and I/O setting parameters, make 
them valid with parameter No.PA19 (parameter write disable). 
 
Display mode transition 
Initial screen 
Function 
Reference 
Status display
Diagnosis
Alarm
Basic setting 
parameters
Gain/filter 
parameters
Extension setting 
parameters
I/O setting 
parameters
button
MODE
 
Servo status display. 
 appears at power-on. (Note) 
 
 
 
Section 6.3
Sequence display, external signal display, forced 
output signal (DO), test operation, software 
version display, VC automatic offset, servo motor 
series ID display, servo motor type ID display, 
servo motor encoder ID display, parameter write 
inhibit, next deactivation display. 
Section 6.4
Current alarm display, alarm history display, 
parameter error No. display, point table error No. 
display. 
 
 
Section 6.5
Display and setting of basic setting parameters. 
 
 
 
 
Section 6.6
Display and setting of gain filter parameters. 
 
 
 
 
Display and setting of extension setting 
parameters. 
 
 
 
Display and setting of I/O setting parameters. 
 
 
 
 
Note. When the axis name is set to the servo amplifier using MR Configurator, the axis name is displayed and the servo status is then 
displayed.