Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
6 -  3 
6. DISPLAY AND OPERATION SECTIONS 
 
6.3 Status display 
The servo status during operation is shown on the 5-digit, 7-segment LED display. Press the "UP" or "DOWN" 
button to change display data as desired. When the required data is selected, the corresponding symbol 
appears. Press the "SET" button to display its data. At only power-on, however, data appears after the symbol 
of the status display selected in parameter No.PC36 has been shown for 2[s]. 
The servo amplifier display shows the lower five digits of 16 data items such as the motor speed. 
 
6.3.1 Display transition 
After choosing the status display mode with the "MODE" button, pressing the "UP" or "DOWN" button changes 
the display as shown below. 
DOWN
Regenerative load ratio
Effective load ratio
Peak load ratio
Instantaneous torque
Cumulative feedback 
pulse
Within one-revolution position 
(1 pulse unit)
Servo motor speed
Within one-revolution position 
(100 pulse unit)
Droop pulse
ABS counter
Cumulative command 
pulse
Load inertia moment ratio
Command pulse 
frequency
Bus voltage
UP
To Bus voltage
To Cumulative feedback pulse
Analog speed command 
voltage
Analog speed limit voltage
Analog torque command 
voltage