13. COMMUNICATION FUNCTION 
 
13.3.7 Initialization 
After the slave station is switched on, it cannot reply to communication until the internal initialization processing 
terminates. Hence, at power-on, ordinary communication should be started after. 
 
(1) 1s or longer time has elapsed after the slave station is switched on; and 
 
(2) Making sure that normal communication can be made by reading the parameter or other data which does 
not pose any safety problems. 
 
13.3.8 Communication procedure example 
The following example reads the set value of alarm history (last alarm) from the servo amplifier of station 0. 
 
Data item 
Value 
Description 
Station number 
Servo amplifier station 0 
Command 33 
Read 
command 
Data No. 
10 
Alarm history (last alarm) 
 
Checksum  30H  33H  33H  02H  31H  30H  03H   FCH
1 0
STX
ETX
3
3
Yes
No
Yes
No
No
No
Yes
Yes
Yes
No
[0][3][3]            [1][0]
[0]
Axis No. Command
Data No.
Data
Start
Data make-up
Checksum calculation and
addition
Addition of SOH to make
up transmission data
Data transmission
Data receive
Is there receive data?
3 consecutive times?
Error processing
Other than error code
[A]   [a]?
Receive data analysis
End
300ms elapsed?
3 consecutive times?
Error processing
100ms after EOT transmission
STX
ETX
46H 43H
SOH
F C
Transmission data
3
3
STX
1 0 ETX
Master station     slave station
Master station     slave station
Master station     slave station
0