Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
15 -  21 
15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
15.2.1 Installation direction and clearances 
CAUTION 
Install the equipment in the specified direction. Not doing so can cause a failure. 
Leave the specified clearances between the converter unit/drive unit and the 
control box inside walls or other equipment. Not doing so can cause a failure. 
 
 
(1) Installation 
 
POINT 
 
Make sure to connect a drive unit to the right side of a converter unit as shown in 
the diagram. 
 
 
80mm or
more
Side view
Front view
100mm or
 more
120mm or more
30mm or 
more
30mm or
more
Cooling fan
exhaust
Air 
intake
Converter unit
Drive unit
Top 
Bottom
 
(2) Mounting dimensional diagram 
9.5
Converter unit
punched hole
Drive unit
punched hole
4-M6 screw
300
20
260
281
Approx. 9.5
Approx. 20
4-M6 screw
W1
W3
W2
W4
Approx. W5
Approx. W3
W5
[Unit: mm]
Drive unit model 
Dimensions 
W1 W2 W3 W4 W5  A 
MR-J3-DU30KA, 37KA, 
45KA4, 55KA4 
300
260 20 281 9.5 M6 
MR-J3-DU30KA4, 
37KA4 
240
120 60 222  9  M5 
 
 
 
 
 
 
 
(3) Others 
When using heat generating equipment such as the regenerative option, install them with full consideration 
of heat generation so that the converter unit and drive unit is not affected. 
Install the converter unit and drive unit on a perpendicular wall in the correct vertical direction.