15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
15.3 Signals and wiring 
WARNING 
Any person who is involved in wiring should be fully competent to do the work. 
Before wiring, turn off the power and wait for 20 minutes or longer until the charge 
lamp turns off. Then, confirm that the voltage between L  and L  is safe with a 
voltage tester and others. Otherwise, an electric shock may occur. In addition, 
always confirm from the front of the converter unit whether the charge lamp is off or 
not. 
Ground the converter unit drive unit and the servo motor securely. 
Do not attempt to wire the converter unit drive unit and servo motor until they 
have been installed. Otherwise, you may get an electric shock. 
The cables should not be damaged, stressed excessively, loaded heavily, or 
pinched. Otherwise, you may get an electric shock. 
 
 
CAUTION 
Wire the equipment correctly and securely. Otherwise, the servo motor may 
operate unexpected resulting in injury. 
Connect cables to correct terminals to prevent a burst, fault, etc. 
Ensure that polarity ( ,  ) is correct. Otherwise, a burst, damage, etc. may occur. 
The surge absorbing diode installed to the DC relay for control output should be 
fitted in the specified direction. 
Otherwise, the emergency stop and other protective circuits may not operate. 
Converter unit
   drive unit
DOCOM
Control output 
signal
DICOM
24VDC
RA
For sink output interface
     
Converter unit
   drive unit
DOCOM
Control output 
signal
DICOM
24VDC
RA
For source output interface
 
Use a noise filter, etc. to minimize the influence of electromagnetic interference, 
which may be given to electronic equipment used near the converter unit drive 
unit. 
Do not install a power capacitor, surge killer or radio noise filter (FR-BIF-(H) option) 
with the power line of the servo motor. 
When using the regenerative resistor, switch power off with the alarm signal. 
Otherwise, a transistor fault or the like may overheat the regenerative resistor, 
causing a fire. 
Do not modify the equipment. 
During power-on, do not open or close the motor power line. Otherwise, a 
malfunction or faulty may occur.