15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
POINT 
 
Explanations on the following item are the same as those for servo amplifiers 
with 22kW or less. Refer to the section below for details. 
I/O signal connection example  Refer to section 3.2. 
Signal (device) explanations  Refer to section 3.5. 
Detailed description of the signals Refer to section 3.6. 
Interfaces  Refer to section 3.8. 
Treatment of cable shield external conductor  Refer to section 3.9. 
Grounding  Refer to section 3.12. 
The pins with the same signal name are connected in the drive unit. 
 
 
15.3.1 Magnetic contactor control connector (CNP1) 
WARNING 
Make sure to connect the magnetic contactor wiring connector to the converter 
unit. If the connector is not connected, an electric shock may occur since CNP1-1 
and L
11
 are always conducting. 
 
 
By enabling the control function of the magnetic contactor (parameter No.PA02
1 (initial value)), main 
circuit power supply can be shut off automatically when an alarm occurs on the converter unit or the drive unit. 
Used to select the output of the external magnet contactor drive signal.
0: No used
1: Used (initial value)
1
Parameter No.PA02