15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW) 
 
No.  Symbol 
Name and function 
Initial 
value 
Unit 
Setting 
range 
PA12  *DIF  Input filter setting 
Select the input filter. 
Input signal filter
If external input signal causes chattering due to noise, etc., input 
filter is used to suppress it.
0: None
1: 1.777[ms]
2: 3.555[ms]
3: 5.333[ms]
0 0
0
 
0002h  
Refer 
to 
Name 
and 
function 
column.
PA13  
For manufacturer setting 
0000h   
 
PA14 
Do not change this value by any means. 
0000h 
PA15  
0000h 
PA16  
0000h 
PA17  
0000h 
PA18  
0000h 
PA19  
0000h 
 
15.6 Troubleshooting 
15.6.1 Converter unit 
(1) Alarms and warning list 
When an error occurs during operation, the corresponding alarm or warning is displayed. If any alarm or 
warning has occurred, refer to (2) or (3) in this section and take the appropriate action. 
Switch power off, then on to deactivate the alarm. The alarms marked " " in the alarm deactivation column 
of the table can be deactivated by pressing the "RES" key of the converter unit side parameter unit or 
switching on the reset signal (RES). 
 
 
Display Name 
Alarm deactivation 
 
 
Display
Name 
Power Error 
 
Warning 
A.91 Overheat 
warning 
OFF ON reset  
A.E0 
Excessive regenerative load  
Alarm 
A.10 Undervoltage 
 
  
warning 
A.12 
Memory error 1 (RAM) 
  
 
A.E1 
Overload 
warning 
A.15 
Memory error 2 (EEP-ROM) 
 
 
 
A.E6 
Converter forced stop warning 
A.17 Board 
error 
 
 
 
A.E8 
Cooling fan speed reduction 
A.19 
Memory error 3 (Flash-ROM) 
  
 
warning 
A.30 Regenerative 
error 
(Note)  (Note)
 
   
 
 
A.33 Over 
voltage 
 
 
   
 
 
A.37 Parameter 
error 
 
 
   
 
 
A.38 
MC drive circuit error 
 
 
   
 
 
A.39 Open 
phase 
 
 
   
 
 
A.3A 
Inrush current suppressor circuit  
 
 
   
 
 
error  
 
 
 
A.45 
Main circuit device overheat 
(Note)
 (Note)
 
   
 
 
A.47 
Cooling fan error 
 
 
   
 
 
A.50 Overload 
(Note)
 (Note)
 
   
 
 
A.51 Overload 
(Note)
 (Note)
 
   
 
 
888 Watchdog 
 
 
   
 
 
Note. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.