Mitsumi electronic MR-J3- A Manual De Usuario
15 - 88
15. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
15.9.9 EMC filter (recommended)
For compliance with the EMC directive of the IEC/EN Standard, it is recommended to use the following filter.
Some EMC filters are large in leakage current.
(1) Converter unit Drive unit
Some EMC filters are large in leakage current.
(1) Converter unit Drive unit
Converter unit
Drive unit
Recommended filter
(Soshin Electric)
Mass [kg]
Model
Leakage current
[mA]
MR-J3-CR55K MR-J3-DU30KA
MR-J3-DU37KA HF3200A-UN
9
18
MR-J3-CR55K4
MR-J3-DU30KA4 to MR-J3-DU55KA4
TF3150C-TX
5.5
31
(2) Connection example
1
2
3
4
5
6
E
(Note)
Power supply
Power supply
L
1
L
2
L
3
L
11
L
21
Converter unit
Drive unit
L
11
L
21
MC
NFB
EMC filter
Note. For power supply specifications, refer to section 15.1.3.