Mitsumi electronic MR-J3- A Manual De Usuario

Descargar
Página de 670
 
 
16 -  3 
16. PARAMETER UNIT (MR-PRU03) 
 
16.2 Specifications 
Item Description 
Model 
MR-PRU03 
Power supply 
Supplied from the servo amplifier (drive unit) 
Functions 
Parameter mode 
Basic setting parameters, Gain/filter parameters, Extension setting 
parameters, I/O setting parameters 
Monitor mode (Status display) 
Cumulative command pulses, Command pulse frequency, Analog speed 
command voltage/Analog speed limit voltage, Analog torque command 
voltage/Analog torque limit voltage, Feedback pulse value, Servo motor 
speed, Droop pulse, Regenerative load ratio, Effective load ratio, Peak load 
ratio, Instantaneous torque, Within one-revolution position, ABS counter, Load 
inertia moment ratio, Bus voltage 
Diagnosis mode 
External I/O display, motor information 
Alarm mode 
Current alarm, Alarm history 
Test operation mode 
JOG operation, Positioning operation, DO forced output, Motor-less operation
Display section 
LCD system (16 characters 4 lines) 
Environment 
Ambient temperature 
10 to 55  (14 to 131 ) (non-freezing) 
Ambient humidity 
90 RH or less (non-condensing) 
Storage temperature range 
20 to 65  ( 4 to 149 ) (non-freezing) 
Storage humidity range 
90 RH or less (non-condensing) 
Ambience 
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, 
dust and dirt 
Mass [g] ([lb]) 
130 (0.287) 
 
16.3 Outline dimension drawings 
[Unit: mm] 
72
15
10.5
48
13
24
40
5-M3 screw
5-   4 hole
40
Punched hole
16.5
11.75
23.75
1.25
Panel cut dimension
Front face
Side face
Back face