A776 (B780) Programming Guide 
A776-PG00001 C 12/09 
Chapter 5: Programming commands
Formulas
The waiting time is t × 100 ms for every macro execution.
specifies macro executing mode when the LSB (least significant bit) m = 0
The macro executes times continuously at the interval specified by t when the LSB (least significant bit) of  
m
 = 1.
Exceptions
If this command is received while a macro is being defined, the macro definition is aborted and the definition is 
cleared.
If the macro is not defined or if r is 0, nothing is executed.
MICR commands
MICR reading
These commands control the Magnetic Ink Character Recognition (MICR) check reader, including how it parses the 
character strings on checks.
The section, MICR parsing, describes how to create a parsing format and how to create and maintain an exceptions 
table.
Read MICR data and transmit
ASCII 
ESC w 1 
 
 
Hexadecimal  1B 77 01  
 
A776:  
1B 77 01 = read & transmit MICR, position for endorsement 
 
1B 77 02 (B780 only)  B780:  
1B 77 01 = wait for check, read & transmit MICR, eject check 
 
 
 
B780:  
1B 77 02 = wait for check, read & transmit MICR, position for endorsement 
Decimal 
27 119 1 
Default: 
All data returned
Reads and transmits the MICR data and adds a carriage return (0x0D). One status byte precedes the MICR characters.
If no parsing format is selected with either of the define parsing format commands (see below), all data will be 
returned, which is the default.
Status 
Status byte value
Good read, data follows 
0x00
Bad read, data follows 
0x01
No check present, no data 
0x02
Paper jam, no data 
0x03
No MICR characters, no data 
0x04
MICR characters 
ASCII 
Hexadecimal
Numerics 
0 ... 9 
0x30 ... 0x39
Unrecognized character 
0x3F
Space 
 
0x20
Amount symbol 
0x26
Dash symbol 
‘ 
0x27
“on us” symbol 
0x28
Transit symbol 
0x29