Or, to set the width of the printing area to two inches at the default horizontal motion unit of 1/203 units per inch, 
send the four-byte string:
 
GS  W  150  1
Where 2 inches = 406/203, and 406 = (1 X 256) + 150.
Exceptions
This command is effective only at the beginning of a line. If the setting exceeds the printable area, the maximum value 
of the printable area is used. The maximum printable area is 576 dots on the receipt and 420 dots on the slip. 
    
 
 

  

    
  
 

  

 
 
 
 
 
Text characteristics commands
These commands control what the printed information looks like, selection of character sets, definition of custom-
defined characters, and setting of margins. The commands are described in order of their hexadecimal codes.
Select double-wide characters
ASCII 
DC2 
Hexadecimal  12 
Decimal 
18
Prints double-wide characters. The printer is reset to single-wide mode after a line has been printed or the clear printer 
(0x10) command is received. Double-wide characters may be used in the same line with single-wide characters.
Select single-wide characters
ASCII 
DC3 
Hexadecimal  13 
Decimal 
19
Prints single-wide characters. Single-wide characters may be used in the same line with double-wide characters.
Select 90 degree counter-clockwise rotated print
ASCII 
ESC DC2 
Hexadecimal  1B 12 
Decimal 
27 18
Rotates characters 90 degrees counter-clockwise. The command remains in effect until the printer is reset or until a 
clear printer (0x10), select or cancel upside down print (1B 7B) or cancel rotated print (1B 56) command is received.
Exceptions
This command is valid only at the beginning of a line.
Rotated print and non-rotated print characters cannot be used together in the same line.
Related information