Introduction 
 
Video Recorder - User Manual 
 
3
 
Table 1-1   Specifications (continued) 
Program Capability 
Number of 
Programs 
 
Memory can store 96 programs for a single channel programmer, 48 programs for a dual 
channel programmer, 32 programs for a three channel programmer, and 24 for a four 
channel programmer.  Programs can also be stored to floppy disk.  Programmer has ability 
to start a program at a predetermined time. 
Number of 
Segments 
63 segments per profile 
Ramping Capability 
Ramp X - Ramp rate is set by specifying x degrees per second, per minute, or per hour. 
 
Ramp T - Ramp rate is set by selecting the time to go from previous setpoint to next 
setpoint in t time. 
 
Ramp E - Ramp rate is set to increment by 
SP for every pulse of a digital input. 
 
Value Duration Ramp - Ramp rate is based on the start value of the ramp and the time 
specified to reach the next soak start value. 
Ramp Time Range 
0-9,999,999 hours, minutes, or seconds. 
Soak 
Guaranteed or non-guaranteed.  Can be applied to ramp or soak segment or across entire 
profile/program. 
Soak time range 
0-9,999,999 hours, minutes, or seconds. 
Program Cycling 
Entire programs or portions of a program can be cycled up to 99 times.  Loops can be 
nested up to 4 deep. 
Startup/Shutdown 
Can be set up to use a predefined startup profile separate from the normal processing 
programs.  Shutdown profile can be attached to the end of a profile and can be jumped to 
for emergency shutdown. 
PV Hot Start 
Can start the profile at the point where the present PV value first intersects the profile. 
Batch Programming 
1 to 255 Batch numbers.  Batch number is assigned by the programmer and is incremented 
automatically when batch is started. 
Using a keyboard or bar code reader and the front keyboard connector, a batch can be 
labeled with a name of up to 8 characters. 
Profile Events 
Up to 16 events can be defined in each segment of a profile.  Each event’s state is 
activated at the beginning of the segment and is held throughout the segment.