Introduction
Video Recorder - User Manual
3
Table 1-1 Specifications (continued)
Program Capability
Number of
Programs
Programs
Memory can store 96 programs for a single channel programmer, 48 programs for a dual
channel programmer, 32 programs for a three channel programmer, and 24 for a four
channel programmer. Programs can also be stored to floppy disk. Programmer has ability
to start a program at a predetermined time.
channel programmer, 32 programs for a three channel programmer, and 24 for a four
channel programmer. Programs can also be stored to floppy disk. Programmer has ability
to start a program at a predetermined time.
Number of
Segments
Segments
63 segments per profile
Ramping Capability
Ramp X - Ramp rate is set by specifying x degrees per second, per minute, or per hour.
Ramp T - Ramp rate is set by selecting the time to go from previous setpoint to next
setpoint in t time.
setpoint in t time.
Ramp E - Ramp rate is set to increment by
∆
SP for every pulse of a digital input.
Value Duration Ramp - Ramp rate is based on the start value of the ramp and the time
specified to reach the next soak start value.
specified to reach the next soak start value.
Ramp Time Range
0-9,999,999 hours, minutes, or seconds.
Soak
Guaranteed or non-guaranteed. Can be applied to ramp or soak segment or across entire
profile/program.
profile/program.
Soak time range
0-9,999,999 hours, minutes, or seconds.
Program Cycling
Entire programs or portions of a program can be cycled up to 99 times. Loops can be
nested up to 4 deep.
nested up to 4 deep.
Startup/Shutdown
Can be set up to use a predefined startup profile separate from the normal processing
programs. Shutdown profile can be attached to the end of a profile and can be jumped to
for emergency shutdown.
programs. Shutdown profile can be attached to the end of a profile and can be jumped to
for emergency shutdown.
PV Hot Start
Can start the profile at the point where the present PV value first intersects the profile.
Batch Programming
1 to 255 Batch numbers. Batch number is assigned by the programmer and is incremented
automatically when batch is started.
automatically when batch is started.
Using a keyboard or bar code reader and the front keyboard connector, a batch can be
labeled with a name of up to 8 characters.
labeled with a name of up to 8 characters.
Profile Events
Up to 16 events can be defined in each segment of a profile. Each event’s state is
activated at the beginning of the segment and is held throughout the segment.
activated at the beginning of the segment and is held throughout the segment.