Alarms and Warnings
312779E
115
Alarms and Warnings
NOTE: Do not use the fluid in the line that was dis-
pensed off ratio as it may not cure properly.
System Alarms
System alarms alert you of a problem and help prevent 
off-ratio spraying. If an alarm occurs, operation stops 
and the following occurs:
Buzzer sounds (for E-2 only; see page 32 to set for 
all alarms).
Status bar on the EasyKey shows the alarm E-Code 
with a description (see Table 16).
System Warnings
Table 16 lists the System Warning Codes. Warnings do 
not stop operation or sound an alarm. They are saved in 
the date/time stamped log, which can be viewed on a 
PC, using the ProMix 2KS Web Interface (see manual 
313386).
To Reset Alarm and Restart
NOTE: When an alarm occurs be sure to determine the 
E-Code before resetting it. See Table 16. If you forget 
which E-Code occurred, use the Alarms Screen (page 
27) to view the last 10 alarms, with date and time 
stamps.
To reset alarms, see Table 17. Many alarms can be 
cleared by simply pressing the Alarm Reset 
 
key. 
Table 16: System Alarm/Warning Codes
Code Description
Details
E-1
Communication Error Alarm
Page 116
E-2
Potlife Alarm
Page 116
E-3
Ratio High Alarm
Page 117
E-4
Ratio Low Alarm
Page 118
E-5
Overdose A/B Dose Too Short 
Alarm
Page 119
E-6
Overdose B/A Dose Too Short 
Alarm
Page 119
E-7
Dose Time A Alarm
Page 120
E-8
Dose Time B Alarm
Page 120
E-9
Mix in Setup Alarm
Page 121
E-10
Remote Stop Alarm
Page 121
E-11
Purge Volume Alarm
Page 121
E-12
CAN Network Communication Error 
Alarm
Page 122
E-13
High Flow Alarm
Page 122
E-14
Low Flow Alarm
Page 122
E-15
System Idle Warning
Page 123
E-16
Setup Change Warning
Page 123
E-17
Power On Warning
Page 123
E-18
Defaults Loaded Warning
Page 123
E-19
I/O Alarm
Page 124
E-20
Purge Initiate Alarm
Page 125
E-21
Material Fill Alarm
Page 125
E-22
Tank A Low Alarm
Page 125
E-23
Tank B Low Alarm
Page 125
E-24
Tank S Low Alarm
Page 125
E-25
Auto Dump Complete Alarm
Page 126
E-26
Color/Catalyst Purge Alarm
Page 126
E-27
Color/Catalyst Fill Alarm
Page 126