Alarm Troubleshooting 
116
312779E
Alarm Troubleshooting
Table 17. Alarm Troubleshooting
E-1: COMM ERROR
Cause
Solution
No power to the EasyKey.
Connect power to EasyKey.
No power to Fluid Station. The intrinsically safe power 
cable between the EasyKey and Fluid Station is not con-
nected.
Verify that the cable is correctly connected. See Installa-
tion manual.
No power to Fluid Station. The fluid control board fuse is 
blown.
Verify condition of fuse and replace if necessary. See 
Repair-Parts manual.
The fiber optic cable between the EasyKey and Fluid 
Station is not connected.
Verify that the cable is correctly connected. See Installa-
tion manual.
The fiber optic cable is cut or bent.
Verify that the cable has not been cut or bent at a radius 
smaller than 1.6 in. (40 mm).
Dirty fiber optic cable ends.
Disconnect fiber optic cable ends and clean with a 
lint-free cloth.
A communication cable or connector failed.
Replace cable.
E-2: POTLIFE ALARM
Cause
Solution
The potlife time has been exceeded for the mixed mate-
rial. 
Press the Alarm Reset 
 
key to stop the audible 
alarm. Purge the system with solvent, fresh mixed mate-
rial, or a new color:
Solvent Purge - See Purging Mixed Material on 
page 95. The system purges until the preset purge 
time is complete.
New Mixed Material Purge - Go to Mix mode and 
spray the required volume to restart the timer.
Color Change - Perform a color change, see page 
102.
NOTICE
To prevent mixed material from curing in the equip-
ment, do not shut off power. Follow one of the solu-
tions at right.